Tuesday, February 9, 2016

Kaiser Super Notch Filter

10.1088/1742-6596/252/1/012005 - IOPscience
After exiting the filter, the plasma expanded through a homogenizer device composed of concentric magnets and allowed focused using an Olympus microscope, and a Kaiser Super-Notch filter was used to suppress the elastically scattered light. ... Access Content

Compact Raman Spectrometer System For Low Frequency ...
Compact Raman spectrometer system for low frequency spectroscopy fabricated holographically in a glass material with optical densities ranging from 4 to 6 per notch filter at the standard Raman laser (Kaiser Optical System) and thick holographic glass (Ondax). -300 -200 -100 0 ... Read Document

Buick Skylark - Wikipedia, The Free Encyclopedia
The Buick Skylark is a passenger car produced by Buick. Buick Super Buick Century Buick Special: Powertrain; Engine: 322 cu in (5.3 L) Nailhead V8: The previous V6 was discontinued and the associated tooling was sold to Kaiser Industries, ... Read Article

Sites.fas.harvard.edu
Subject: Image Created Date: 20051215143306-0500 ... Fetch Here

Strong Polarized Enhanced Raman Scattering Via Optical ...
Strong Polarized Enhanced Raman Scattering via Optical Tunneling through Random Parallel Nanostructures in Au Thin Films beam using an appropriate optical filter. Finally, the substrate used in this work does not require any special condition for patterning ... Read Document

A Cell-based Method To Monitor The Interaction Between ...
A Cell-based Method to Monitor the Interaction between Hepatitis B Virus Capsid and Surface Proteins Kaiser super-notch filter), and subsequently their sizes were determined by using spatially correlated AFM (Veec o Bioscope/Multimode, USA) ... Retrieve Document

Chapter 2 Structure And Oxidation State Of Silica-Supported ...
Structure and Oxidation State of Silica-Supported Manganese Oxide Catalysts and Reactivity for Acetone Oxidation Using Spex Lexel 95) as a light source, a holographic notch filter (Kaiser, Super Notch Plus) to reduce Rayleigh scattering, a single stage monochromator (Spex, ... Read Content

Sites.fas.harvard.edu
High Transmission Outside Notch KAISER OPTICAL SYSTEMS, INC. A KAISER AEROSPACE & ELECTRONICS COMPANY 371 Parkland Plaza P.o. Box 983 Ann Arbor, Ml 48106-0983 4.0 points for a 532 nm filter 350 nm to 1064 nm Available Wavelength Range ... Document Retrieval

Fluorescent II VI Semiconductor Quantum Dots In Living Cells ...
Super notch filter (NF Kaiser Optics Super Notch Plus with 350 cm-1 rejection bandwidth) was used as a mirror to reflect both the femtosecond and the CW Ti:Sapphire laser beams to the microscope and to act as a notch filter for the backscattered light. ... Return Document

Probing Metal Support Interactions Under Oxidizing And ...
Probing Metal-Support Interactions under Oxidizing and Reducing Conditions: In Situ Raman and Infrared Spectroscopic and Scanning Transmission Electron The Rayleigh scattering component was blocked by a notch filter (Kaiser Super Nothch) ... Doc Viewer

Chapter 3 Distinguishing Between Reaction Intermediates And ...
Distinguishing between Reaction Intermediates and Spectators: A Kinetic Study of Acetone Oxidation Using holographic notch filter (Kaiser, Super Notch Plus), a single stage monochromator (Spex, 500 M), and a CCD detector (Spex, Spectrum One). ... Document Viewer

INTEGRATED REMOTE RAMAN AND LIBS INSTRUMENT WITH 532 NM LASER ...
INTEGRATED REMOTE RAMAN AND LIBS INSTRUMENT WITH 532 NM LASER EXCITATION coupled directly to a Kaiser F/1.8 HoloSpec transmission-grating spectroscope through a 100-µm slit after passing through a 532-nm holo-graphic super-notch filter (NF) to remove the reflected ... Access Content

Continuous-Flow Reactor For Kinetic Analysis Of Rapid ...
Continuous-Flow Reactor for Kinetic Analysis of Rapid Hydrothermal Reactions by Raman Spectroscopy of which a holographic filter (Kaiser, Super Notch Plus) is placed. The light is dispersed by a grating (1200 lines/mm) and is detected with a CCD array ... View Full Source

A Fluorescent Stilbenoid Dendrimer For Solution-processed ...
Kaiser Super-Notch-Plus filter was used to suppress the elastic scattered light. The incident power was reduced to few mW in order to avoid local heating of the samples. Electroluminescence (EL) spectra and Spectral luminance from ... Read Full Source

NANO LETTERS Nanohole-Enhanced Raman Scattering
Nanohole-Enhanced Raman Scattering fundamental laser light was rejected using a Kaiser super-notch filter, and the remaining radiation was directed through a Kaiser Holospec f/1.4 spectrograph coupled with an Andor CCD detector (model DV-401-BV). ... Retrieve Document

Experimental Set Up For Combined LIBS And Raman Spectroscopy ...
Experimental Set Up for Combined LIBS and Raman Spectroscopy with 1064 & 532 nm Laser Beams graphic Sharma et al. (2007) Kaiser holo- spectrograph TS Nd:YAG laser with 1064 and 532 nm beams SNF = super notch filter, T = telescopes, L = laser, BE = beam expander, S = sample, ... Retrieve Here

Structural Determination Of Bulk And Surface Tungsten Oxides ...
Structural Determination of Bulk and Surface Tungsten Oxides with UV-vis Diffuse Reflectance Spectroscopy and Raman Spectroscopy notch filter (Kaiser Super Notch). The visible excitation was generated by a Nd-YAG doubled diode pumped laser (Coherent ... Fetch Here

Remote Pulsed Laser Raman Spectroscopy System For Detecting ...
Remote pulsed laser Raman spectroscopy system for detecting water, ice, Raman spectrum is analyzed using a spectrograph equipped with a holographic super notch filter to eliminate Rayleigh the signal passed through a notch filter (Kaiser Optical 532 nm Holographic SuperNotch-Plus ... Access Full Source

MrGundogtrainer - YouTube
In this video you will see where Steve catches flatheads from the Ohio River in the daytime using cut bait. Learn where to look for them during the day. Please visit our sponsors: ... View Video

No comments:

Post a Comment